Ross-controls ROSS MODULAR I Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Acessórios para eletricidade Ross-controls ROSS MODULAR I. Ross Controls ROSS MODULAR I User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 56
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Premium Pneumatic Controls Since 1921
ISO Valves
and
Serial Bus Communication
Premium Pneumatic Controls Since 1921
EtherNet/IP
TM
ControlNet
TM
PROFIBUS
®
DeviceNet
TM
CANopen
BULLETIN 600
Vista de página 0
1 2 3 4 5 6 ... 55 56

Resumo do Conteúdo

Página 1 - BULLETIN 600

Premium Pneumatic Controls Since 1921ISO Valves andSerial Bus CommunicationPremium Pneumatic Controls Since 1921 EtherNet/IPTM ControlNetTM

Página 2 - Standard Definitions

10 © 2012, ROSS CONTROLS®. All Rights Reserved.SpecificationsSeries W66, Size 00: 0.55 Cv (18mm)Series W66, Size 0: 1.1 Cv (26mm)Materials of Construct

Página 3 - Table of Contents

11www.rosscontrols.comFunction*4-Way2-PositionRemote Pilot 56Solenoid Pilot 764-Way3-PositionRemote Pilot 57Solenoid Pilot 77Dual 3-Way2-PositionNorma

Página 4 - Serial Bus System

12 © 2012, ROSS CONTROLS®. All Rights Reserved.Size 00 (18mm) & Size 0 (26mm) Common Model Numbers Single Solenoid2-PositionDouble Solenoid2-Posit

Página 5 - 5www.rosscontrols.com

13www.rosscontrols.comfor ISO Bases (5599-2)5/2 Valves – Single Solenoid Pilot ISO Avg. Port Valve Model Weight Size CV Size Number* lb. (kg

Página 6

14 © 2012, ROSS CONTROLS®. All Rights Reserved.for ISO Bases (5599-2)5/2 Valves – Single Remote Pressure Control Spring Return ISO Avg. Port Valve

Página 7 - I/O - Remote Configuration

15www.rosscontrols.comSize 00 & 0 Manifold / Subbase Kits Manifold and Subbase Kit Ordering CodeSubbase KitsManifold KitsSeries W66, Size 0 Subbas

Página 8

16 © 2012, ROSS CONTROLS®. All Rights Reserved.Size 2Size 3Size 1Subbase KitsSize 2Size 3Size 1Manifold KitsManifold and Subbase Kit Ordering CodeWiri

Página 9 - 9www.rosscontrols.com

17www.rosscontrols.comSingle Solenoid2-PositionDouble Solenoid2-PositionDouble Solenoid3-Position Closed Center3-Position Open Center3-Position Power

Página 10 - 15407-1 & 2

18 © 2012, ROSS CONTROLS®. All Rights Reserved.Size 00 & 0 Manifold / Subbase / End Plate Kits RPJLP02RPEJ02DIN Rail MountDIN Rail Mount#1 Port#5

Página 11 - Basic Size

19www.rosscontrols.comMaximum Solenoids Energized Simultaneously (Interconnect Circuit Boards)Size 00 & 0 (15407-2)1. List Manifold Assembly call

Página 12 - Double Solenoid

2 © 2012, ROSS CONTROLS®. All Rights Reserved. WARNINGFAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED H

Página 13

20 © 2012, ROSS CONTROLS®. All Rights Reserved.Maximum Solenoids Energized Simultaneously (Interconnect Circuit Boards)Size 1, 2 & 3 (5599-2)#14 E

Página 14 - All Rights Reserved

21www.rosscontrols.comSeries W66, Size 00 & 0 25-PinEnd PlatesSeries W66, Size 00 & 0 19-PinEnd PlatesSeries W66, Size 00 & 0 Non-Collecti

Página 15 - Plug-in, Series W66 (15407-2)

22 © 2012, ROSS CONTROLS®. All Rights Reserved.Size 1 19-Pin Round End PlatesSize 1 25-Pin D-Sub End PlatesSize 1 Non-Collective Wiring End PlatesSize

Página 16 - R PS4011 55 A – C P

23www.rosscontrols.comAccessoriesCollective Wiring Module Kits Size 2 & 3Size Kit Number25-Pin, D-Sub Module*†RSCD251MCM23, 12-Pin*†RSCM231MC19-Pi

Página 17

24 © 2012, ROSS CONTROLS®. All Rights Reserved.Accessories15407-25599Size1, 2, 3 Main GalleySize1, 2, 3 Pilot GalleyManifold Port Isolation KitsMain G

Página 18 - End Plate Kit

25www.rosscontrols.com• RemoteAirPilotOperatedforhard-to-reachpressure control.• UnregulatedPilotPressuretovalveforconsistent valve shif

Página 19 - AA 00 D 0 04 –

26 © 2012, ROSS CONTROLS®. All Rights Reserved.Interposed Regulator Kit Ordering CodeOrdering Components • ManifoldorSubbaseKitrequired.• Interp

Página 20 - AA H1 D 0 03 –

27www.rosscontrols.com5599-1 ShownRemote Pilot Access Plate KitsSize Port SizeKit NumberNPT BSPP “G”Size 1 1/8" RPS401500CP RPS401501CPSize 2 1/8

Página 21 - Series W66

28 © 2012, ROSS CONTROLS®. All Rights Reserved.AccessoriesPlug-In5599-2Size 2 Shown• Bothadjustmentscrewsarelocatedonthe 12 end of the unit.•

Página 22 - R PS40 20 L2 0 C P

29www.rosscontrols.comTemperature Rating-15°C to 49°C (5°F to 120°F) Ambient.Response Time** (ms)## Size 00 (12), Size 0 (25)** With 100 PSIG supply

Página 23 - R PS40 26 L2 0 C P

3www.rosscontrols.comTable of ContentsSerial Bus Systems ...

Página 24 - Blank Station Kits

30 © 2012, ROSS CONTROLS®. All Rights Reserved.25-Pin, D-Sub Cable SpecificationsCommonPin“13”isratedfor3amps.Commonwireratingmustbe greate

Página 25 - Accessories

31www.rosscontrols.comTechnical & Wiring Information16-Point Terminal StripTerminalValveSolenoidGGC 12345678910111213141516C12345678910 11 12 13 1

Página 26 - R PS4037 1 6 6 C P

32 © 2012, ROSS CONTROLS®. All Rights Reserved.Service & Repair KitsSeries W65 Replacement Pilot Assembly & CoilDescription Model NumberPilot

Página 27 - 27www.rosscontrols.com

33www.rosscontrols.comService & Repair KitsSpring Range Size 1 Size 2 & 30 to 30 PSIG RPS4050030P RPS4150030BP2 to 60 PSIG RPS4050060P RPS4150

Página 28 - Interposed Flow Controls

34 © 2012, ROSS CONTROLS®. All Rights Reserved.Serial Bus SystemTMCommunication Modules• ACommunicationModulesupportsuptoamaximum of 63 I/O mo

Página 29 - Flow Rating (Cv)

35www.rosscontrols.comSerial Bus Product CompatibilityDeviceNet™AdapterRPSSCDMControlNet AdapterRPSSCCNAEtherNetAdapterRPSSCENAPROFIBUSAdapterRPSSCPBA

Página 30 - Electrical Connectors

36 © 2012, ROSS CONTROLS®. All Rights Reserved.Communication Modules*†§ DeviceNet™ (M18 or M12)RPSSCDM18PA (M18) orRPSSCDM12A (M12)10 to 28.8VDC†§ C

Página 31 -  DS=DoubleSolenoidValve

37www.rosscontrols.comValve Driver Module32 Point Module – Size 00, 0, 1, 2, & 3 RPSSV32A*†24 Output Cable – Size 00 & 0 RPS5624P†25 - 32 Outp

Página 32 - Quantity 10

38 © 2012, ROSS CONTROLS®. All Rights Reserved.Specifying a Serial Bus SystemFollow these steps as you specify your Serial Bus system:Step 1Select a C

Página 33 - 33www.rosscontrols.com

39www.rosscontrols.comFor These Features Remember SelectBehaves as a slave device on the Main Network and a master on the PointBus.Allows a group of I

Página 34 - I/O Modules

4 © 2012, ROSS CONTROLS®. All Rights Reserved.• AcompleteSerialBuscommunicationoffering for all ISO valves.• UL,C-ULandCEcertications (as

Página 35 - * Hilscher North America

40 © 2012, ROSS CONTROLS®. All Rights Reserved.0123021346574567MODNETRPSSN8M12A24V dc In0123021346574567MODNETRPSST8M12A24V dc Out01234567MODNET0 12 3

Página 36 - I/O Modules*

41www.rosscontrols.comDigital I/O ModulesChoose digital I/O modules when you need:• Input Modules. An input module responds to an input signal in the

Página 37 - Bus Extender Cable

42 © 2012, ROSS CONTROLS®. All Rights Reserved.Analog I/O ModulesThe Serial Bus analog modules support: on-board, channel-level data alarming (four se

Página 38 - . All Rights Reserved

43www.rosscontrols.comAnalog Input ModulesRPSSNACM12A RPSSNAVM12ANumber of Inputs 2 2Keyswitch Position 3 3Input Signal Range 4…20 mA0…20 mA 0…10V

Página 39 - Selecting a Network

44 © 2012, ROSS CONTROLS®. All Rights Reserved.Valve Driver ModuleRPSSV32AThe RPSSV32A valve driver module provides an interface between the Serial Bu

Página 40

45www.rosscontrols.comExpansion Power UnitThe RPSSSE24A expansion power unit passes 24VDC field power to the I/O modules to the right of it. This unit

Página 41 - Digital I/O Modules

46 © 2012, ROSS CONTROLS®. All Rights Reserved.Typical ConfigurationsPower Distribution OptionsSerial Bus Communication Adapter and I/O ModulesAn auxil

Página 42 - Relay Output Module

47www.rosscontrols.comSerial Bus Relay Output Module CablesPart NumberRecommended Rockwell Automation Patchcord (double-ended) Recommended Rockwell Au

Página 43 - Analog Output Modules

48 © 2012, ROSS CONTROLS®. All Rights Reserved.Serial Bus DeviceNet™ and Auxiliary Power CablesPart Number NetworkRecommended Rockwell Automation Netw

Página 44

49www.rosscontrols.comPower Supply Distance RatingModules are placed to the right of the power supply. Each Serial Bus module can be placed in any of

Página 45 - Expansion Power Unit

5www.rosscontrols.com32 Output Valve Driver ModuleI/O Module Base• CentralizedSerialBussystem.• PneumaticsandI/Oareincloseproximitytoone

Página 46

50 © 2012, ROSS CONTROLS®. All Rights Reserved.Holes for M6 (or 1/4")Screws 4 PlacesSlots for M6 (or 1/4")Screws 4 PlacesCommunicationsModul

Página 47 - Select Cables and Cordsets

51www.rosscontrols.comSerial Bus Related Publications*Part Number Description Instruction Sheet*General Information—Industrial Automation Wiring and G

Página 48 - See www.amphenolrf.com

52 © 2012, ROSS CONTROLS®. All Rights Reserved.Phone Support (8am–5pm Eastern Standard Time, Monday thru Friday) When your process is down, or you hav

Página 49

53www.rosscontrols.comInstallation Safety GuidelinesInstallation Safety Guidelines For Selecting And Using ROSS CONTROLS Products And Related Accessor

Página 50

54 © 2012, ROSS CONTROLS®. All Rights Reserved.Installation Safety Guidelines 2.7. Chemical Compatibility: For more information on plastic component

Página 51

55www.rosscontrols.com 4.5. Routine Maintenance Issues: •Removeexcessivedirt,grimeandclutterfromworkareas.   •Makesureallrequired

Página 52

YourlocalROSSdistributoris:Form A10309© 2012 ROSS CONTROLS®. All Rights Reserved.PDF version only, USA.ROSS CONTROLSTroy, MI, U.S.A.Telephone: +

Página 53 - WARNING:

6 © 2012, ROSS CONTROLS®. All Rights Reserved.M12 Input ModuleCommunication AdapterM23, 12-Pin Output ModuleTerminating BaseModuleTM• AcompleteSeri

Página 54 - 54 © 2012, ROSS CONTROLS

7www.rosscontrols.com• RemoteSerialBussystem.• PneumaticsandI/Oarenotinclose proximity with one another.• M23,12-Pinoutputextensionto

Página 55 - 55www.rosscontrols.com

8 © 2012, ROSS CONTROLS®. All Rights Reserved.TMCommunication AdapterM23, 12-Pin End Plate KitM23, 12-Pin CableBus Extender CableM23, 12-Pin Output Mo

Página 56 - EtherNet/IP

9www.rosscontrols.com• RemoteSerialBussystem.• PneumaticsandI/Oarenotincloseproximitywith one another.• M23,12-Pinoutputextensionto

Comentários a estes Manuais

Sem comentários